{"id":8074,"date":"2020-05-19T16:53:18","date_gmt":"2020-05-19T11:23:18","guid":{"rendered":"https:\/\/triumphias.com\/blog\/?p=8074"},"modified":"2020-05-19T16:53:18","modified_gmt":"2020-05-19T11:23:18","slug":"biodegradable-metal-implants","status":"publish","type":"post","link":"https:\/\/triumphias.com\/blog\/biodegradable-metal-implants\/","title":{"rendered":"Biodegradable metal implants"},"content":{"rendered":"<section class=\"hero-section\" data-type=\"type-1\" data-alignment=\"left\">\n<header class=\"entry-header\"><span style=\"color: #0000ff;\"><strong>Relevance: Prelims: Science and technology<\/strong><\/span><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/slideplayer.com\/slide\/12327099\/73\/images\/23\/Biodegradable+Metals+Iron+%28Fe%29%2C+Magnesium+%28Mg%29+and+Zinc+%28Zn%29%3A.jpg\" alt=\"CHAPTER 4 Biomaterials Metals - ppt video online download\" \/><\/p>\n<p><strong>Why in news?<\/strong><\/p>\n<\/header>\n<\/section>\n<div class=\"entry-content\">\n<p>\u2022 Scientists at the International Advanced Research Centre for Powder Metallurgy and New Materials (ARCI), under the Department of Science &amp; Technology (DST) has developed new generation Iron-Manganese based alloys for biodegradable metal implants for use in humans.<\/p>\n<p><b>About:<\/b><\/p>\n<p>\u2022 Iron-Manganese based alloy Fe-Mn (having Mn composition of more than 29% by weight) is a promising biodegradable metallic implant which exhibits single austenitic phase (non-magnetic form of iron) with MRI compatibility.<\/p>\n<p>\u2022 The alloy also showed a degradation rate in the range of 0.14-0.026 mm per year in the simulated body fluid, which means that the Fe-Mn alloy exhibits mechanical integrity for 3-6 months and completely disappears from the body in 12-24 months.<\/p>\n<p>\u2022 The newly developed Fe-Mn based alloys are suitable for biodegradable stent and orthopedic implant applications.<\/p>\n<p><b>Other highlights:<\/b><\/p>\n<p>\u2022 These Biodegradable materials (Fe, Mg, Zn, and polymer) can participate in the healing process and then degrade gradually by maintaining the mechanical integrity without leaving any implant residues in the human body.<\/p>\n<p>\u2022 These are better alternatives to currently used metallic implants that remain permanently in the human body and can cause long-term side effects like systemic toxicity, chronic inflammation, and thrombosis.<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #0000ff;\"><strong>For more such notes, Articles, News &amp; Views Join our Telegram Channel.<\/strong><\/span><\/p>\n<p><a title=\"telegram Link\" href=\"https:\/\/t.me\/triumphias\" target=\"_blank\"><span style=\"color: #ff0000;\"><strong>https:\/\/t.me\/triumphias<\/strong><\/span><\/a><\/p>\n<p><span style=\"color: #0000ff;\"><strong>Click the link below to see the details about the UPSC \u2013Civils courses offered by Triumph IAS.<\/strong><\/span> <span style=\"color: #ff0000;\"><strong><a style=\"color: #ff0000;\" title=\"Courses available\" href=\"https:\/\/triumphias.com\/pages-all-courses.php\">https:\/\/triumphias.com\/pages-all-courses.php<\/a><\/strong><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Relevance: Prelims: Science and technology Why in news? \u2022 Scientists at the International Advanced Research Centre for Powder Metallurgy and<\/p>\n","protected":false},"author":1,"featured_media":7214,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"footnotes":""},"categories":[123],"tags":[392],"class_list":["post-8074","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-current-affairs","tag-union-public-service-commission-upsc"],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/posts\/8074","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/comments?post=8074"}],"version-history":[{"count":1,"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/posts\/8074\/revisions"}],"predecessor-version":[{"id":8075,"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/posts\/8074\/revisions\/8075"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/media\/7214"}],"wp:attachment":[{"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/media?parent=8074"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/categories?post=8074"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/triumphias.com\/blog\/wp-json\/wp\/v2\/tags?post=8074"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}